SE-Flame-Reflectance VIS-NIR reflection spectrometer by Ocean

$6,499.00

Description

Our FLAME reflection system uses a classic 6 around 1 reflection probe. This was the very first fiber probe developed by Ocean Optics nearly 20 years ago, and it has been used extensively for measuring reflectance for color determination, thin film thickness measurement, reflectance of optics, backscattering in tissue and fluids and even fluorescence. The system includes a light source, reflection probe, white standard, software and holder and of course the VIS-NIR Flame spectrometer.

System Components

FLAME-S-VIS-NIR-ES FLAME-S-VIS-NIR-ESSpectrometer 350 – 1000nm, 25um slit, L2 lens, 1.5nm FWHM 1
OCEANVIEW OceanView spectroscopy software with graphical user interface; 1 license (2 installations, accessible by download only from our secure server) 1
INTSMA-200 Interchangeable Round SMA 200um 1
HL-2000-FHSA-LL HL-2000-LL with filter holder, shutter, attenuator, long-life 1
R400-7-VIS-NIR 400 um Reflection Probe, VIS/NIR, 2 m 1
RPH-1 Reflection Probe Holder for 6.35-mm diameter probes 1
WS-1 Diffuse Reflectance Standard, PTFE 1

Spectrometer Specifications

Specifications FLAME-S-VIS-NIR-ES  
SPECTROSCOPIC
Optical resolution: 1.5 nm FWHM  with 25 micron slit, kit includes 5,10,25,50,100 and 200 um slits that usr can change
Signal-to-noise ratio: 250:1 (full signal)
Dark noise: 50 RMS counts
Dynamic range: 1300:1 for a single acquisition, 8.5 x 10^7 (system)
Integration time: 1 ms – 65 seconds
Stray light: <0.05% at 600 nm; <0.10% at 435 nm
Corrected linearity: >99%
ELECTRONICS
A/D resolution: 16 bit
Power consumption: 250 mA @ 5 VDC
Inputs/Outputs: 8 x  user programmable GPIOs
Trigger modes: 4 modes
Strobe functions: Yes
Gated delay feature: Yes
Connectors: USB, high density 40 pin JAE DD4 connector
DETECTOR
Detector: Sony ILX511B linear silicon CCD array
Detector range: 350 – 1000 nm
Pixels: 2048
PHYSICAL
Dimensions: 88.9 mm x 63.5 mm x 31.9 mm (34.4 mm with feet)
Weight: 265 g

Light Source Specifications

Engineering Specifications
HL-2000-LL Series
Source: Long Lifetime Tungsten Halogen
Wavelength range: 360-2400 nm
Color temperature: 2,800 K
Nominal bulb power: 4.75 W
Typical output power: See chart below
Warm-up time:* 10 minutes
Source lifetime: 10,000 hours (typical)
Stability of optical output: 0.15% peak-to-peak
Drift of optical output: <0.3% per hour
Trigger/shutter: HL-2000-FHSA-LL only
Integrated filter holder & attenuator: HL-2000-FHSA-LL only
Operating temperature: 5 °C – 35 °C
Operating humidity: 5-95% without condensation at 40 °C
Power requirements: 12 VDC
Power consumption: up to 15 W
Dimensions: 6.2 cm x 6 cm x 15 cm
Weight: 0.5 kg
Safety & regulatory: CE; ROHS, WEEE
Replacement bulb: HL-2000-B-LL

*  Warm-up time @23 °C ambient, free airflow, no vibrations

 

Additional information

Weight 6 lbs
Dimensions 13 x 13 x 8 in

Reviews

There are no reviews yet.

Be the first to review “SE-Flame-Reflectance VIS-NIR reflection spectrometer by Ocean”

You may also like…