SE-Flame-FL Ocean Optics Fluorescence Spectrometer System 350 – 1000nm

$6,899.00

Description

Our FLAME emission fluorescence system provides fluorescence emission spectra from 350-1000nm. Excitation is from a high power fiber coupled  LED. The kit comes with a 365nm LED and as an added bonus Spectrecology also includes a 470nm LED that can be switched by the user. The cuvette holder features 4 ports for fluorescence or absorbance measurements, mirror inserts to enhance excitation and emission collection efficiency and a quartz fluorescence cuvette. Spectrecology also includes a pack of 100 4 sided disposable cuvettes.

 

The system includes the following components

Flame-S-VIS-NIR-ESFLAME-S-VIS-NIR-ESSpectrometer 350 – 1000nm, 25um slit, L2 lens, 1.5nm FWHM1
INTSMA-200Interchangeable Round SMA 200um1
LLS-365High-Power LED Light Source, 365nm, SMA Connector1
MLA-LED-470High-Power LED Module, 405nm, includes pre-programmed EEPROM, heatsink, and SMA connector1
CUV-ALL-UVCuvette Holder, 4 collimators, 1-cm path, 200-2000 nm1
CUV-COVERCover for 1-cm Cuvette Holder1
SE-202295Cuvette, 4 clear sides for fluorescence, macro, VIS  100/pK1
3-Q-10Rectangular fluorometer cell, Spectrosil, 10mm1
OceanviewOceanView spectroscopy software with graphical user interface; 1 license (2 installations, accessible by download only from our secure server)1
QP600-025-UV-BX600 um Premium Fiber, UV/VIS, 25 cm2

 

SpecificationsFLAME-S-VIS-NIR-ES 
SPECTROSCOPIC
Optical resolution:1.5 nm FWHM  with 25 micron slit, kit includes 5,10,25,50,100 and 200 um slits that usr can change
Signal-to-noise ratio:250:1 (full signal)
Dark noise:50 RMS counts
Dynamic range:1300:1 for a single acquisition, 8.5 x 10^7 (system)
Integration time:1 ms – 65 seconds
Stray light:<0.05% at 600 nm; <0.10% at 435 nm
Corrected linearity:>99%
ELECTRONICS
A/D resolution:16 bit
Power consumption:250 mA @ 5 VDC
Inputs/Outputs:8 x  user programmable GPIOs
Trigger modes:4 modes
Strobe functions:Yes
Gated delay feature:Yes
Connectors:USB, high density 40 pin JAE DD4 connector
DETECTOR
Detector:Sony ILX511B linear silicon CCD array
Detector range:350 – 1000 nm
Pixels:2048
PHYSICAL
Dimensions:88.9 mm x 63.5 mm x 31.9 mm (34.4 mm with feet)
Weight:265 g

 

NumberCWLFWHM Min Power coupled into a 600 um .22NA fiber Maximum Drive Current (Continuous Mode)Maximum Drive Current (Pulsed Mode) Maximum Duty Cycle (Pulsed Mode) 
LLS-365 365 nm9 nm1 mW500 mA1000 mA50%
LLS-470 470  nm25 nm1 mW1500 mA3000 mA50%

Additional information

Weight7 lbs
Dimensions13 × 13 × 13 in

Reviews

There are no reviews yet.

Be the first to review “SE-Flame-FL Ocean Optics Fluorescence Spectrometer System 350 – 1000nm”