RCT O2 Sensor for Neofox – screw cap & embedded thermistor, 1/4″ OD

$740.00

Clear
SKU: SEOX-RCT Categories: ,

Description

RCT O2 probe sensors use an optical fiber to interrogate a transparent sensor disc coated with an oxygen sensitive fluorophore in a screw on cap on the end of a stainless steel shaft. The oxygen probe sensor cap is easily replaced for changing chemistries or upgrading a damaged sensor disc. The probe has an embedded thermistor and 5′ integrated bifurcated fibers. The fibers and thermistor wire can be extended with SEOX-EXT1000-X extensions.

The probe body or ferrule comes in 1/4″ OD.

Oxygen probe sensor caps are available in 2 chemistries — AP is our most stable general purpose chemistry. HCR is specific for use in hydrocarbon solvents such as toluene, alchols etc.,

The NEOFOX oxygen sensor probe comes with 1 sensor cap. Replacement caps are list under SEOX-RC

The probe come with a factory calibration in 0% and 21.9% O2 and from 25C to 40 C temperature range. Extended range or special calibrations in specific solvents are available at an extra charge (call us with details)

A formulation

Polystyrene matrix

HCR formulation

Sol Gel matrix

**MR formulation

Sol Gel matrix on request only

Response Rate T90 = 3 sec T90 = 1 sec T90 = <1 sec
Dynamic Range (gas) 0 – 760 mmHg

0 – 100% (at 1 atm)

0 – 760 mmHg

0 – 100% (at 1 atm)

0 – 760 mmHg

0 – 100% (at 1 atm)

Dynamic range (DO) 0 – 40 ppm in H2O 0 – 40 ppm in H2O 0 – 40 ppm in H2O
Resolution (gas) 0.04 mmHg

0.005% (at 1 atm)

0.4 mmHg

0.05% (at 1 atm)

0.4 mmHg

0.05% (at 1 atm)

Resolution (DO) 0.002 ppm in H2O 0.002 ppm in H2O 0.002 ppm in H2O
Accuracy 5% of reading 5% of reading 5% of reading
LDL (gas) 0.04 mmHg

0.005% (at 1 atm)

0.4 mmHg

0.05% (at 1 atm)

0.4 mmHg

0.05% (at 1 atm)

LDL (DO) 0.002 ppm in H2O 0.002 ppm in H2O 0.002 ppm in H2O
Drift rate No measureable long term drift, continuous operation 0.0001 % /hr in gas 0.0001 % /hr in gas
Sensor Operating Temperature -50 to 100C -50 to 200C -50 to 200C
Useful Lifetime 3 years 3 years 3 years
Compatibility General purpose gases and aqueous solutions Organic solvents General purpose gases and aqueous liquids
Water Vapor Interference no yes no
Formats Dip coated fibers

Spin coated patches & probes

Dip coated fibers

Spin coated patches & probes

Dip coated fibers

Spin coated patches & probes

Comments Best general purpose probe, longer fluorescence decay yields more resolution, zero drift means stable calibrations Used for organic solvents and gases with organic vapors.  This sensor does respond to water vapor as well as O2 General purpose but with faster response rate than AP chemistry. Does exhibit long term photo-bleaching drift and has less resolution.

 

Additional information

Weight 2 lbs
Dimensions 13 × 13 × 3 in
SEOX chemistry

AP general purpose, HCR hydrocarbon resistant

overcoat

black acrylic, black med grade silicone, none (transparent), white