SEOX-2 Deluxe O2 Meter - Portable Optical Oxygen Sensor System

Complete portable O2 sensor system with 1/4″ screw cap probe with AP and HCR chemistries, 1/16″ coated sensor, standard calibrations, 1mm plastic optical fiber probe, non-invasive sensor patches and associated fibers and accessories

SEOX-2 Optical O2 meter is a ready to go system complete with the following components:

  • NEOFOX-SPORTportable phase fluorometer for measuring optical oxygen sensors. The NEOFOX-SPORT has a rechargeable battery, DPU with display and control buttons, and an SD card slot for storing data. The NEOFOX-SPORT can also connect to your PC with a USB cable and be run by NEOFOXVIEWER software (included). The unit also features a temperature input (thermistor) and analog and digital outputs.
    •  SEOX-RCT250-A Zero Drift O2 Fiber Probe, 1/4″ OD, 7″ long, stainless steel probe with removable screw cap sensor tip. The probe has an embedded thermistor with 5′ lead, and integral fibers with SMA connectors. Two tips are provided, SEOX-RC250CAP-A  for general use and SEOX-RC250CAP-HCR for working in aggressive hydrocarbons.
    • SEOX-F116-A   O2 Fiber Probe, 1000um, 1/16″ OD x 7″ with Zero drift AP chemistry. Useful for measuring O2 in confined volumes.
    • SEOX-AP-POF-1000   Plastic optical fiber oxygen sensor, 6″ long. These sensors feature tolerance to sharp bending, and are lower cost that glass and silica fiber sensors. The plastic sensors do not come pre-calibrated.
    • SEOX-BB-1000-5  Bifurcated glass fiber bundle, 5′  to couple the F116 or the POF sensors to the fiber optic ports on the NEOFOX-GT
    • 21-02 splice bushing – allows you to use the system with any SMA terminated optical O2 sensors.
    • SEOX-PATCH-A O2 AP thick patch, 1/4″ x 1.8mm thick acrylic,  5/pack. These sensor discs can be mounted on the inside of clear containers and measured from the outside by pointing the SEOX-BB-125 probe towards the backside of the disc. This is an excellent method for sampling O2 inside of sealed systems without disturbing the O2 levels.
    • SEOX-BB-125  1/8″ reflective bundle for measuring non-invasive sensor discs.
    • Neofoxviewer software (Windows)
    • Rugged Pelican carrying case
    • Standard O2, temperature calibrations  for the RCT and F116 probes.

    The SEOX-2 offers  the full range of application and deployment opportunities for Zero Drift sensor technology. You enjoy a substantial price advantage over individual components when you buy the kit.

O2 sensor specifications. The AP chemistry probe is available for rental. HCR and MR can be purchased

 

Dimensions 327.6 x 190.5 x 66.5 mm
Weight 928 g
Principle Photoluminescence quenching using a ruthenium compound: sensor measures O2 partial pressure
Parameters measured Luminescence phase shift, AC luminescence intensity temperature (via optional external thermistor) and pressure (via onboard pressure transducer)
Sensor coating formulations General purpose (FOXY), high-sensitivity (FOSPOR) and hydrocarbon-ready (HIOXY)
Media Gases and liquids
Communications USB, analog out
External Power Supply Voltage 4.75 – 5.1 V (5.0 V typical)
Total Power Consumption 6 W (5 V External Power, Charging, Typical)
Total Power Consumption 3.1 W (5 V External Power, Not Charging, Typical)
Total Power Consumption 3.3 W (3.3 V Battery Power, Typical)
NeoFox Modular Power Consumption 2.5 W (3.3V Battery Power, Typical)
Battery Life 3 hours (typical)
Data Logging Rate, Maximum 1 Hz
4-20 mA Output Accuracy at 25 ºC + 160 µA
0-5 V Output Accuracy at 25 ºC + 50 mV
Electronics Operating Temperature 0 – 55 ºC

 

AP formulation

Polystyrene matrix

HCR formulation

Sol Gel matrix

MR formulation

Sol Gel matrix

Response Rate

T90 = 3 sec

T90 = 1 sec

T90 = 1 sec

Dynamic Range (gas)

0 – 760 mmHg

0 – 100% (at 1 atm)

0 – 760 mmHg

0 – 100% (at 1 atm)

0 – 760 mmHg

0 – 100% (at 1 atm)

Dynamic range (DO)

0 – 40 ppm in H2O

0 – 40 ppm in H2O

0 – 40 ppm in H2O

Resolution (gas)

0.04 mmHg

0.005% (at 1 atm)

0.4 mmHg

0.05% (at 1 atm)

0.4 mmHg

0.05% (at 1 atm)

Resolution (DO)

0.002 ppm in H2O

0.002 ppm in H2O

0.002 ppm in H2O

Accuracy

5% of reading

5% of reading

5% of reading

LDL (gas)

0.04 mmHg

0.005% (at 1 atm)

0.4 mmHg

0.05% (at 1 atm)

0.4 mmHg

0.05% (at 1 atm)

LDL (DO)

0.002 ppm in H2O

0.002 ppm in H2O

0.002 ppm in H2O

Drift rate

No measureable long term drift, continuous operation

0.0001 % /hr in gas

0.0001 % /hr in gas

Sensor Operating Temperature

-50 to 100C

-50 to 200C

-50 to 200C

Useful Lifetime

3 years

3 years

3 years

Compatibility

General purpose gases and aqueous solutions

Organic solvents

General purpose gases and aqueous liquids

Water Vapor Interference

no

yes

no

Formats

Dip coated fibers

Spin coated patches & probes

Dip coated fibers

Spin coated patches & probes

Dip coated fibers

Spin coated patches & probes

Review

Best general purpose probe, longer fluorescence decay yields more resolution, zero drift means stable calibrations

Used for organic solvents and gases with organic vapors.  This sensor does respond to water vapor as well as O2

General purpose but with faster response rate than AP chemistry. Does exhibit long term photo-bleaching drift and has less resolution.

 

 

 

SEOX-1 optical oxygen sensor system
Click To Enlarge
  • Item #: SEOX-2
  * Marked fields are required.
Qty*
Price $4,999.00

Related Items

Reviews (0) Write a Review