SE-Flame-REFLECTANCE VIS reflection spectrometer

Our FLAME reflection system uses a classic 6 around 1 reflection probe. This was the very first fiber probe developed by Ocean Optics nearly 20 years ago, and it has been used extensively for measuring reflectance for color determination, thin film thickness measurement, reflectance of optics, backscattering in tissue and fluids and even fluorescence. The system includes a light source, reflection probe, white standard, software and holder and of course the VIS-NIR Flame spectrometer.

 

System Components

FLAME-S-VIS-NIR-ES FLAME-S-VIS-NIR-ES Spectrometer Assembly 1 $3,435.00 $3,435.00
OCEANVIEW OceanView spectroscopy software with graphical user interface; 1 license (2 installations, accessible by download only from our secure server) 1 $214.00 $214.00
INTSMA-KIT KIT of Interchangeable Round SMA  connectors; 5um; 10um; 25um; 50um; 100um and 200um 1 $499.00 $499.00
HL-2000-HP-FHSA HL-2000-FHSA with 20W output 1 $1,631.00 $1,631.00
R400-7-VIS-NIR 400 um Reflection Probe, VIS/NIR, 2 m 1 $619.00 $619.00
RPH-1 Reflection Probe Holder for 6.35-mm diameter probes 1 $113.00 $113.00
WS-1 Diffuse Reflectance Standard, PTFE 1 $306.00 $306.00
         
  TOTAL     $6,817.00
  Promotional Price (through July 3rd)     $6,135.00
  Your Savings     $682.00

Spectrometer Specifications

Specifications FLAME-S-VIS-NIR-ES  
SPECTROSCOPIC
Optical resolution: 1.5 nm FWHM  with 25 micron slit, kit includes 5,10,25,50,100 and 200 um slits that usr can change
Signal-to-noise ratio: 250:1 (full signal)  
Dark noise: 50 RMS counts
Dynamic range: 1300:1 for a single acquisition, 8.5 x 10^7 (system)
Integration time: 1 ms – 65 seconds  
Stray light: <0.05% at 600 nm; <0.10% at 435 nm
Corrected linearity: >99%
ELECTRONICS
A/D resolution: 16 bit
Power consumption: 250 mA @ 5 VDC
Inputs/Outputs: 8 x  user programmable GPIOs
Trigger modes: 4 modes
Strobe functions: Yes
Gated delay feature: Yes
Connectors: USB, high density 40 pin JAE DD4 connector
DETECTOR
Detector: Sony ILX511B linear silicon CCD array  
Detector range: 350 - 1000 nm  
Pixels: 2048  
PHYSICAL
Dimensions: 88.9 mm x 63.5 mm x 31.9 mm (34.4 mm with feet)
Weight: 265 g

Light Source Specifications

Engineering Specifications HL-2000-HP Family
Source: High-powered Tungsten Halogen
Wavelength Range: 360-2400 nm
Color temperature: 3,000 K
Nominal bulb power: 20 W
Typical output power: See chart below
Warm-up time:* 10 minutes
Source lifetime: 1,000 hours (typical)
Stability of optical output: 0.25% peak-to-peak
Drift of optical output: <0.3% per hour
Trigger/shutter input signal: TTL; Up to 2.5 Hz maximum
Trigger/shutter connection: SUB-D-15 pin
Integrated filter holder: HL-2000-HP-FHSA only
Operating temperature: 5 °C – 35 °C
Operating humidity: 5-95% without condensation at 40 °C
Power requirements: 24 VDC
Power consumption: up to 30 W
Dimensions: 6.2 x 6 x 15 cm
Weight: 0.5 kg
Safety & regulatory: CE; ROHS, WEEE
Replacement bulb: HL-2000-HP-B
*  Warm-up time @23 °C ambient, free airflow, no vibrations
Output Power  
The table below reports typical output power coupled into a 600 μm UV/VIS fiber and measured with an optical power meter integrated from 200-1100 nm.
Model Output
HL-2000-HP-FHSA 8.4 mW
   
Shutter/Trigger Options
Available only for the listed models
Engineering Specifications HL-2000-HP-FHSA
Trigger/shutter input signal: TTL; Up to 2.5 Hz maximum
Trigger/shutter connection: SUB-D-15 pin

 

 


FLAME miniature fiber optic spectrometer set up for reflection and color measurements
Click To Enlarge
  • Item #: SE-Flame-REFLECTANCE-VIS
  * Marked fields are required.
Qty*
Price $7,042.00

Related Items

Reviews (0) Write a Review
No Reviews. Write a Review